What are the precautions for using a compression atomizer? We have also provided a brief introduction to this issue before, but we found that there are still many customers who do not understand. Coincidentally, today I would like to take this opportunity to explain to everyone. I hope it can bring good help to relevant parties.
When using a compression atomizer, it is important to note that the inhalation time for each atomization should not exceed 20 minutes. If liquid is used, it should be included in the total liquid intake. If the dosage is blindly excessive, it may cause pulmonary edema or water poisoning. Of course, there is sometimes a possibility of increased airway resistance. After several hours of nebulization inhalation, breathing difficulties actually worsen. In addition to being alert to pulmonary edema, it may also be due to worsening conditions such as liquefaction, dilation, and obstruction of airway secretions. So we need to pay attention to the prevention of respiratory reinfection. Due to the fact that compression nebulizers can carry bacteria into the alveoli, it may cause secondary Gram negative bacterial infections. Bacterial sources: oral, upper respiratory, and aerosol infections in children. Therefore, compression atomizers should not only strengthen the hygiene of the mouth, nose, and throat, but also pay attention to the disinfection of indoor air and various medical equipment.
The compression atomizer is used by nurses after doctors prescribe nebulized medication to the machine. Patients with symptoms such as difficulty breathing and increased heart rate are prohibited from using it. When using, it is also recommended to place it in a flat and stable place, not on carpets or rough surfaces to avoid blocking ventilation, and the compression atomizer should not cover the surface of the compressor during operation. This machine is an electrical appliance. It should be noted that compression atomizers should not be used in unattended and dangerous humid environments. Alternatively, it should be noted that after each patient uses the mouthpiece, inner core, and outer shell, they should be washed with clean water and soaked in a 1:100 "84" solution for 30-45 minutes. Inject 1:100 "84" solution into the guide tube with a syringe every day, and soak and disinfect the outside with 1:100 "84" solution. After 30 minutes, rinse with clean water and air dry for later use. Then unplug and turn off the compressor before cleaning. Wipe the surface of the compressor with a damp cloth. Do not allow liquids to enter the ventilation opening.
The above content is the precautions for using a compression atomizer that the editor has explained to friends. Other knowledge points about other devices will continue to be updated in the next issue. Remember to follow the website more to not miss out on exciting content. As the flagship product of our factory, we would like to thank our new and old customers for their strong support. While ensuring the reliability of product quality, we also benefit our customers. After all, it is well-known in this industry, with reasonable prices and guaranteed quality. You will definitely not be disappointed.